-40%

Miniature Circuit Breaker Micro Circuit Breaker DZ47-60 1P C16 16A

$ 3.08

Availability: 31 in stock
  • Current Type: AC
  • All returns accepted: Returns Accepted
  • Number of Poles: 1
  • Model: DZ47-60 1P C16
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Current Rating: 16A
  • Color: White
  • Operation Method: On/Off
  • Voltage: 230/400V
  • Refund will be given as: Money Back
  • MPN: DZ47-60 1P C16
  • Brand: CHINT
  • Country/Region of Manufacture: China

    Description

    infrared thermometer DZ47-60 1P C16
    CHINT rated current of 60A and below, to act overload, short-circuit protection.
    Product Description
    infrared thermometer Range of application:
    DZ47-60 miniature circuit breaker, only available for sales in Commonwealth of Independent States, is mainly used in the circuit of AC 50Hz/60Hz, rated voltage of 400V and below, rated current of 60A and below, to act overload, short-circuit protection. It can also turn on or off the electrical appliance and lighting circuit infrequently under normal conditions, but not applicable for direct protection of high sensibility and high capacitive load of motor and electric equipment, capacitor cabinets, etc.
    Standard: IEC 60898-1.
    infrared thermometer Normal working conditions:
    environmental temperature: 5 C ~ + 40 C; The average no more than 35 C within 24 h.
    Height: installation location altitude does not exceed 2000 m.
    infrared thermometer the main parameters and technical performance:
    according to the rated current In points: 1A, 2A, 3A, 4A, 5A, 6A, 10A, 15A, 16A, 20A, 32A, 40A, 50A, 60A.
    the number:
    A. unipolar;
    B. diode;
    C. three pole;
    D. quadrupole.
    according to instantaneous tripping circuit breaker type points:
    A.C type (5 ~ 10 in);
    B.D type (10 ~ 16 in);
    mechanical and electrical life:
    Home Garyical life: not less than 4000 times;
    Mechanical life: not less than 10000 times.
    infrared thermometer DZ47-60(C) Type
    Rated current(A)
    number
    Voltage (V)
    On-off capacity (A)
    C1-C40
    1
    230/400
    6000
    C1-C40
    2,3,4
    400
    6000
    C50-C60
    1
    230/400
    4000
    C50-C60
    2,3,4
    400
    4000
    infrared thermometer DZ47-60(D) Type
    Rated current(A)
    number
    Voltage (V)
    On-off capacity (A)
    D1-D60
    1
    230/400
    4000
    D1-D60
    2,3,4
    400
    4000
    Connection: for 25 mm below the wire connection, 2.0 N · m torque.
    Rated current(A)
    Copper wires nominal cross-sectional area (mm)
    1-6
    1
    10
    1.5
    16,20
    2.5
    25
    4
    32
    6
    40,50
    10
    60
    16